Home » Blog » Insulation Laminate Standards: NEMA vs IEC vs GB/T

Insulation Laminate Standards: NEMA vs IEC vs GB/T

Insulation laminate standards cause constant confusion in cross-border sourcing, and it’s usually not because the materials are actually different. It’s because three different standards bodies gave the same laminate three different names. A buyer in the U.S. asks for “G10.” A supplier in China quotes “3240.” A datasheet from a European distributor lists “EPGC201.” In most cases, all three describe the same underlying epoxy-glass laminate. However, “most cases” is exactly where sourcing mistakes happen, since the standards aren’t perfectly interchangeable and supplier documentation isn’t always consistent about which one it actually certifies against.

Quick answer: NEMA LI 1 (U.S.), IEC 60893 (international), and GB/T 1303 (China) all cover the same family of glass-fabric epoxy laminates. The grades cross-reference reasonably well: G10 ≈ EPGC201, FR4 ≈ EPGC202, G11 ≈ EPGC203, FR5 ≈ EPGC204, and 3240 sits close to EPGC201/G10 territory. The catch is that GB/T sub-part numbering and thermal-class terminology vary across supplier documentation. Because of that, the safe move is always to check the actual test report behind a part, not just the grade name on the invoice.

Comparison of global insulation laminate standards, showing NEMA LI 1 (USA), IEC 60893 (International), and GB/T 1303 (China) epoxy glass materials.
Comparison of global insulation laminate standards, showing NEMA LI 1 (USA), IEC 60893 (International), and GB/T 1303 (China) epoxy glass materials.

Why Three Sets of Insulation Laminate Standards Exist

  • NEMA LI 1, published by the National Electrical Manufacturers Association, is the U.S. industry standard for industrial laminated thermosetting products. It’s where familiar grade names like G10, FR4, G11, FR5, and G7 originate.
  • IEC 60893 is the International Electrotechnical Commission’s standard for insulating materials. Most of Europe, Asia, and international trade documentation use it as the reference point. It designates the same material family using EPGC, or Epoxy Glass Cloth, codes.
  • GB/T 1303 is China’s national standard series for glass-fabric-reinforced laminates. Domestic manufacturers reference it constantly, and it shows up throughout Chinese sourcing and export documentation.

None of these bodies coordinated their naming, since the standards were written decades apart in different regions. That’s why a cross-reference table is useful, even if it seems obvious.

Grade Cross-Reference Table

NEMA GradeIEC 60893 DesignationChina GB/T 1303 (Common Reference)Resin SystemFlame RetardantTypical Thermal Class
G-10EPGC201Close to “3240” in common trade usageEpoxyNoB (~130°C)
FR-4EPGC202GB/T 1303 series (epoxy, flame-retardant)EpoxyYes (UL 94 V-0 with additives)B (~130°C)
G-11EPGC203GB/T 1303.2High-Tg epoxyNoF (~155°C, some grades to 180°C)
FR-5EPGC204GB/T 1303 series (high-Tg, flame-retardant)High-Tg epoxyYesF (~155°C)
G-7IEC 60893-3-6 seriesNot commonly cross-referencedSiliconeSelf-extinguishingH (~200°C)
—EPGC308—High-Tg epoxyNo~180°C (no direct NEMA equivalent)

A note on the GB/T column: the NEMA-to-IEC relationship is well-documented and fairly consistent across suppliers, but GB/T grade references vary more between manufacturers. Chinese trade documentation widely uses “3240” to describe a G10-adjacent epoxy laminate under IEC 60893-3-2 (EPGC201). Even so, you’ll also see it cross-referenced to different GB/T 1303 sub-parts depending on the supplier. Treat this column as a starting point for a conversation with your supplier, not a substitute for their actual test report.

Where These Insulation Laminate Standards Diverge

The grade names line up well enough for general sourcing. That said, three things commonly trip up buyers who treat the table above as gospel.

GB/T “3240” isn’t a single locked specification the way G10 is under NEMA. It’s a widely used trade name that maps closely to EPGC201. Different manufacturers, however, apply slightly different resin formulations and Tg targets under that same name. If your application has tight mechanical or thermal requirements, ask for the supplier’s actual test data against GB/T 1303, rather than relying on the “3240” label alone.

Thermal class terminology doesn’t always mean the same thing across standards. NEMA’s “Class B” and IEC’s “Class B” per IEC 60085 both reference roughly 130°C, which is convenient. Still, the underlying test methods and margins aren’t identical. A material that just clears one standard’s threshold isn’t guaranteed to clear the other’s by the same margin.

Flame-retardant chemistry isn’t standardized between regions. FR4 sourced in North America commonly uses brominated flame retardants. FR4-equivalent material sourced elsewhere may instead use phosphorus-nitrogen systems, particularly where halogen-free compliance is required under RoHS or REACH. Both chemistries can meet UL 94 V-0. If your project has a halogen-free requirement, though, the grade name alone won’t tell you which chemistry you’re getting; only the datasheet will.

A Practical Sourcing Checklist

  1. Ask for the specific standard and clause the material is certified against. “IEC 60893-3-2, EPGC201” tells you far more than “G10-equivalent.”
  2. Request the actual test report, not just a datasheet that references a standard in passing. Reputable suppliers can provide batch-level test data.
  3. Confirm flame-retardant chemistry explicitly if your project has RoHS, REACH, or halogen-free requirements. Don’t assume UL 94 V-0 alone answers that question.
  4. Double-check thermal class against your real operating temperature, not just the nominal grade name. “B” and “F” class boundaries sit close enough to typical use cases that a small margin can matter.
  5. When in doubt, cross-reference IEC 60893, since it serves as the common language between NEMA and GB/T sourcing.

FAQs About NEMA, IEC, and GB/T Insulation Laminate Standards

Is China’s “3240” laminate the same as NEMA G10? They’re closely related, and both describe a non-flame-retardant epoxy-glass laminate. That said, “3240” isn’t a single locked specification the way G10 is under NEMA LI 1. Properties can vary somewhat between suppliers using the “3240” name, so it’s worth confirming the actual test report rather than assuming full equivalence.

What does EPGC stand for in IEC 60893? EPGC stands for Epoxy Glass Cloth. The number that follows — 201, 202, 203, or 204 — identifies the specific grade: non-flame-retardant, flame-retardant, high-Tg non-flame-retardant, or high-Tg flame-retardant, respectively.

Does FR4 meet the same standard everywhere in the world? FR4 as a grade name stays consistent, but the flame-retardant chemistry behind it can differ by region. Brominated systems are common in North America, while phosphorus-nitrogen or other halogen-free systems are more common where RoHS or REACH compliance is required. Both can meet UL 94 V-0.

Why does my supplier’s datasheet reference a different GB/T sub-part than another supplier’s? GB/T 1303 covers a family of glass-fabric laminates across several sub-parts, and manufacturers don’t always cite the same sub-part for materials sold under the same trade name. It’s a real inconsistency in the market. That’s exactly why confirming the actual test data matters more than matching grade names.

Bottom Line

NEMA, IEC, and GB/T describe largely the same family of insulation laminate standards, and the cross-reference table above gets you to the right conversation with a supplier faster than starting from scratch. Even so, treat it as a translation layer, not a guarantee. The grade name gets you in the right neighborhood, but the test report confirms the material meets your project’s real requirements. If you’re sourcing insulation laminates across regions and want help matching specifications, get a quote, and our team can walk through the standards your project needs to meet. You can also review our certifications and compliance documentation directly.