Home » Blog » FRP Fibreglass Reinforced Epoxy Bolts

FRP Fibreglass Reinforced Epoxy Bolts

The FRP Epoxy Bolt is made from premium epoxy resin and reinforced with continuous, high-strength, uniform fibreglass, manufactured using a controlled pultrusion process. So the FRP Bolt exhibits incredible strength and durability and provides electrical insulation and chemical resistance to the elements. The perfectly designed are a special replacement for metal fasteners, offering corrosion resistance, electrical conductivity, or weight savings in application conditions.

FRP bolts are manufactured as either full-thread or partial-thread designs. The FRP Bolt is well-suited for use in electrical insulation systems, chemical plants, and offshore structures, as well as FRP grating assembly, wastewater treatment facilities, telecommunications towers, and in non-metallic infrastructure.

Advantages of FRP Epoxy Bolts

1. Excellent Electrical Insulation

A 100% non-metallic structure ensures high dielectric strength, making it safe for high-voltage equipment, substations, and electrical cabinets.

2. Corrosion-Free Performance

Resistant to acids, alkalis, moisture, saltwater, and industrial chemicals—far superior to steel in corrosive environments.

3. High Strength-to-Weight Ratio

Lightweight composite structure with tensile strength up to 600–1000 MPa, suitable for both structural and non-structural applications.

4. Dimensional Stability

Low thermal expansion and excellent fatigue resistance ensure long-term performance under temperature changes and mechanical loading.

5. Non-Magnetic & RF Transparent

Won’t interfere with sensors, antennas, or signal transmission—ideal for telecom and MRI applications.

6. UV & Weather Resistant

Optional UV-stabilised resin systems for outdoor installations.

7. Customizable

Available in various colours, thread types, diameters, and lengths. OEM/ODM orders are welcome.

Applications of FRP Epoxy Bolts

Electrical & Power Systems

  • Transformers, switchgear, and electrical cabinets
  • High-voltage insulation structures
  • Non-conductive fastening for substations

Chemical & Corrosive Environments

  • Acid/alkali processing equipment
  • Pump bases and pipe supports
  • Offshore platforms and coastal facilities

Water & Wastewater Treatment

  • FRP grating installation
  • Non-metallic structural supports
  • Walkways, handrails, platforms

Construction & Infrastructure

  • FRP profiles and structural connections
  • Lightweight or non-metallic buildings
  • Corrosion-free fasteners for tunnels and bridges

Telecom & Electronics

  • Antenna mounts
  • Radar and signal equipment
  • Non-magnetic fastening assemblies

Main Technical Specifications

Available DiametersM6, M8, M10, M12, M14, M16, M18, M20
Most popular: M8 / M10 / M12 / M16
Standard Lengths40 mm – 300 mm (regular)
300 mm – 1000 mm (customize)
Mechanical PropertyTypical Value
Tensile Strength600–1000 MPa
Flexural Strength300–450 MPa
Shear Strength120–200 MPa
Elastic Modulus20–35 GPa
Density1.8–2.0 g/cm³
Dielectric Strength>10 kV/mm
Temperature Resistance120°C–180°C (depending on epoxy resin)
Material CompositionContinuous E-glass fibers (≥ 65% by weight)
Epoxy resin matrix
Optional UV stabilizers, flame retardants, color pigments
Weaving method of fiberglass fabriclayered plain woven bolt
layered twill-woven bolt

Common quality issues

Common quality issues, causes, and impacts in epoxy bolt production (covering raw material, processing, and curing processes):

  • Thread Precision Failure: Caused by improper cutting parameters (excessive speed/tool wear) or blank dimension deviation. Leads to thread slipping, loose fitting, and poor assembly tightness.
  • Head Cracking/Chipping: Excessive milling impact or incomplete curing of epoxy rods can cause head-edge damage, reducing load-bearing capacity.
  • Dimensional Deviation: Inaccurate cutting length or turning/milling positioning errors result in non-conforming total length, thread length, or head thickness, leading to installation adaptation failure.
  • Incomplete Curing: Insufficient curing temp/time of epoxy rods or unhardened adhesive during repair. Shows sticky surface, low hardness, and easy deformation/cracking in long-term use.
  • Bubbles/Voids: Uneven resin impregnation during pultrusion or poor heat dissipation during cutting causes internal/surface bubbles, reducing corrosion resistance and mechanical performance.
  • Surface Scratches/Damage: Improper protection during post-processing transportation/storage results in scratches that damage the epoxy protective layer and increase the risk of corrosion.
  • Mechanical Performance Failure: Insufficient glass fibre content or abnormal pultrusion parameters result in inadequate tensile/shear strength, failing working condition force requirements.

We are a professional FRP composite factory specialising in high-temperature composite epoxy sheets. We provide OEM/ODM customisation for diameters, lengths, and colours; Logo printing & packaging; and Engineering support for assembly design. We promise the quality and have quality assurance

  • Strict pultrusion control, High precision processing
  • 100% inspection of fibre content, appearance, and bolt accuracy
  • Mechanical property test report available